{"product_id":"fluke-376-fc-true-rms-ac-dc-clamp-meter","title":"Fluke 376 FC True-RMS AC\/DC Clamp Meter","description":"\u003cdiv style=\"font-family:Arial,sans-serif;line-height:1.6;color:#333;max-width:800px;\"\u003e\n\u003cp\u003eThe Fluke 376 FC is a new True-RMS AC\/DC clamp meter with built-in Fluke Connect wireless capability, capable of measuring AC\/DC current up to 1000A via its integral hall-effect jaw and up to 2500A AC using the included iFlex flexible current probe (model i2500). The meter is CAT III 1000V \/ CAT IV 600V rated for safe use at the service entrance and distribution panel level, and measures AC\/DC voltage to 1000V, resistance, continuity, frequency, and AC voltage with the rotary selector; front-panel buttons provide INRUSH, MIN\/MAX, and data logging functions. The iFlex rogowski coil accessory — visible in the photos with its yellow termination connector — threads around large or oddly shaped conductors where a rigid jaw cannot fit, extending the meter's usability to bus bars and bundled cables up to 2500A AC. Powered by two AA (IEC LR6) batteries as marked on the rear label, the 376 FC ships complete with the iFlex probe, test leads, carrying strap, and the Fluke soft zippered carrying case shown in the photos.\u003c\/p\u003e\n\u003ch3 style=\"margin-top:24px;margin-bottom:12px;font-size:16px;color:#56555b;border-bottom:2px solid #85c94f;padding-bottom:6px;\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eFluke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eModel \/ MPN\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e376 FC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eMeter Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eTrue-RMS AC\/DC Clamp Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eWireless Connectivity\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eFluke Connect (Wi-Fi\/Bluetooth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eAC Current Range (Jaw)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e0.1 A – 1000 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eDC Current Range (Jaw)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e0.1 A – 1000 A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eAC Current Range (iFlex)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eUp to 2500 A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eAC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e1 mV – 1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eDC Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e1 mV – 1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eVoltage Safety Rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eResistance Measurement\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eYes (Ω function visible on selector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eFrequency Measurement\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eYes (Hz function visible on selector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eInrush Current Capture\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eYes (dedicated INRUSH button)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eMin\/Max Recording\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eYes (MIN MAX button)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eData Logging\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eYes (LOG 2sec function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eBattery Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e2x AA (IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eIncluded Accessories\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eiFlex probe, test leads, strap, soft case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eiFlex Probe Model\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003ei2500 (2500A max, visible on probe label)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eCondition\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eManufacturer Address\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eFluke Corp, 1529 Seaway Blvd, Everett WA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eCountry of Assembly\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eMalaysia (visible on rear label)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"DDT and More","offers":[{"title":"Default Title","offer_id":48770315223255,"sku":"4916t99C","price":285.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0736\/0626\/7095\/files\/fluke-376-fc-true-rms-clamp-meter-1.jpg?v=1781188037","url":"https:\/\/dansdiscounttools.com\/products\/fluke-376-fc-true-rms-ac-dc-clamp-meter","provider":"Dan's Discount Tools","version":"1.0","type":"link"}