{"product_id":"schneider-electric-lrd21-tesys-12-18a-690v-class-10a-thermal-overload-relay","title":"Schneider Electric LRD21 TeSys 12-18A 690V Class 10A Thermal Overload Relay","description":"\u003cdiv style=\"font-family:Arial,sans-serif;line-height:1.6;color:#333;max-width:800px;\"\u003e\n\u003cp\u003eThe Schneider Electric TeSys LRD21 is a thermal IEC overload relay with an adjustable current setting range of 12 to 18 A and a rated voltage of 690 V AC. It uses a thermal sensing method with Trip Class 10A and has a front-mounted dial, blue RESET button and red STOP button. It has one NO (97-98) and one NC (95-96) auxiliary contact, and the power terminals are marked 2\/T1, 4\/T2 and 6\/T3. It is designed for use with LC1D18 and LC1D38 contactors, mounting directly via its plug-in pins, and is listed to UL 508, CSA C22.2 No. 14, EN\/IEC 60947-4-1, EN\/IEC 60947-5-1 and ATEX 94\/9\/CE, and is RoHS compliant. This unit is new.\u003c\/p\u003e\n\u003ch3 style=\"margin-top:24px;margin-bottom:12px;font-size:16px;color:#56555b;border-bottom:2px solid #85c94f;padding-bottom:6px;\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eMPN\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eLRD21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eLRD 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eCurrent Range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e12-18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eMinimum Overload Current\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e12.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eMaximum Overload Current\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e18.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eTrip Class\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eStarter Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eIEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eSensing Method\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eThermal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eOverall Width\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eCompatible Contactors\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eLC1D18, LC1D38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eAuxiliary Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e1 NO, 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eReset Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eManual\/Auto, RESET and STOP buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eUL 508, CSA C22.2 No. 14, EN\/IEC 60947-4-1, EN\/IEC 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eHazardous Area Approval\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eATEX 94\/9\/CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eRoHS\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eCompliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eDirect contactor mount, plug-in pins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eDark Gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eCurrent Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv class=\"ddt-disclaimer\" style=\"margin-top:16px;padding-top:8px;border-top:1px solid #ddd;font-family:Arial,sans-serif;font-size:12px;line-height:1.5;color:#555;\"\u003e\u003cp\u003eDan’s Discount Tools is an independent reseller. We are not an authorized dealer or distributor for any brand we sell, and we are not affiliated with or endorsed by any manufacturer. Brand names are used only to identify the item. This item is sold without the manufacturer’s or distributor’s warranty. Our own return policy applies.\u003c\/p\u003e\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68237106905303,"sku":"7537xM1","price":185.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0736\/0626\/7095\/files\/schneider-electric-lrd21-1.jpg?v=1795630832","url":"https:\/\/dansdiscounttools.com\/products\/schneider-electric-lrd21-tesys-12-18a-690v-class-10a-thermal-overload-relay","provider":"Dan's Discount Tools","version":"1.0","type":"link"}