{"product_id":"schneider-electric-lrd340-30-40a-tesys-thermal-overload-relay-everlink","title":"Schneider Electric LRD340 30-40A TeSys Thermal Overload Relay EverLink","description":"\u003cdiv style=\"font-family:Arial,sans-serif;line-height:1.6;color:#333;max-width:800px;\"\u003e\n\u003cp\u003eThe Schneider Electric TeSys LRD340 is a new 3-pole bimetallic thermal overload relay from the TeSys Protect series, featuring EverLink screw-clamp terminals rated for 75°C copper conductors with a torque spec of 70 lb-in. The current setting range is 30–40 A (adjustable via front-panel dial, scale marked in FLMC units), with a maximum operating voltage of 690 V AC at 50\/60 Hz and an impulse withstand voltage (Uimp) of 6 kV. The relay is Class 10A (Cl.10A) per IEC\/EN 60947-4-1, providing overload and phase-loss protection; it includes one NO (97-98) and one NC (95-96) auxiliary contact, a blue manual RESET button, and a red STOP button, with automatic reset capability enabled. Compatible for direct plug-in mounting with Schneider LC1D contactor series (LC1D••A frame, e.g., LC1D40A), and carries UL Listing (File 170M, 600 V AC max), CSA, CE, UKCA, EAC, CCC, and IRAM approvals; SCCR is 100 kA at 600 V with Class J or CC fuse protection. Manufactured in France under the Telemecanique \/ Schneider Electric brand.\u003c\/p\u003e\n\u003ch3 style=\"margin-top:24px;margin-bottom:12px;font-size:16px;color:#56555b;border-bottom:2px solid #85c94f;padding-bottom:6px;\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eSchneider Electric (Telemecanique)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eMPN\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eLRD340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eTeSys Protect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eThermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eCondition\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eCurrent Setting Range\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e30–40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eOverload Class\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eClass 10A (Cl.10A) per IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eMax Operating Voltage (Ue)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e690 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eImpulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eAuxiliary Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e1 NO (97-98), 1 NC (95-96)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eReset Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eManual (blue button) \u0026amp; Auto reset enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eStop Function\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eRed STOP button (manual trip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eTerminal Type\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eEverLink screw-clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eWire Rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e75°C CU wire only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eTerminal Torque\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e70 lb-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eCompatible Contactor\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eLC1D••A frame (e.g., LC1D40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eSCCR – Class J or CC Fuse\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e100 kA @ 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eSCCR – CB\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e100 kA @ 480 V; 50 kA @ 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eUL Listing\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eFile 170M, 600 V AC max, Industrial Control Eq.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eIEC\/EN 60947-4-1, UL, CSA, CE, UKCA, EAC, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f8f9fa;\"\u003e\n\u003ctd style=\"padding:8px 12px;font-weight:600;color:#56555b;border-bottom:1px solid #eee;width:40%;\"\u003eGrainger \/ Distributor Part #\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border-bottom:1px solid #eee;\"\u003e6KYC6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"AnneMarie","offers":[{"title":"Default Title","offer_id":49545809166551,"sku":"8823t111P","price":68.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0736\/0626\/7095\/files\/tesys-lrd340-thermal-overload-relay-1.jpg?v=1786026959","url":"https:\/\/dansdiscounttools.com\/products\/schneider-electric-lrd340-30-40a-tesys-thermal-overload-relay-everlink","provider":"Dan's Discount Tools","version":"1.0","type":"link"}